Refine your search:     
Report No.
 - 
Search Results: Records 1-4 displayed on this page of 4
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

JAEA Reports

Evaluation of heat exchange performance for intermediate heat exchanger in HTTR

Tochio, Daisuke; Nakagawa, Shigeaki

JAERI-Tech 2005-040, 39 Pages, 2005/07

JAERI-Tech-2005-040.pdf:1.88MB

In High Temperature Engineering Test Reactor (HTTR) of 30 MW, the generated heat at reactor core is finally dissipated at the air-cooler by way of the heat exchangers of the primary pressurized water cooler and the intermediate heat exchanger. Heat exchangers in main cooling system of HTTR should satisfy two conditions, achievement of reactor coolant outlet temperature 850 $$^{circ}$$C/950 $$^{circ}$$C and removal of reactor generated heat 30 MW. That is, heat exchange performance should be ensured as that in heat exchanger designing. In this report, heat exchange performance for Intermediate heat exchanger (IHX) in main cooling system is evaluated with rise-to-power-up test and in-service operation data. Moreover, the applicability of IHX thermal-hydraulic design method is discussed with comparison of evaluated data with designed value.

Journal Articles

Heat exchanger performance in main cooling system on high temperature test operation at High Temperature Gas-Cooled Reactor 'HTTR'

Tochio, Daisuke; Nakagawa, Shigeaki; Furusawa, Takayuki*

Nihon Genshiryoku Gakkai Wabun Rombunshi, 4(2), p.147 - 155, 2005/06

High Temperature Engineering Test Reactor (HTTR) of high temperature gas-cooled reactor at JAERI achieved the reactor outlet coolant temperature of 950$$^{circ}$$C for the first time in the world at Apr. 19, 2004. To remove of generated heat at reactor core and to hold reactor inlet coolant temperature as specified temperature, heat exchangers in HTTR main cooling system should have designed heat exchange performance. In this report, heat exchanger performance is evaluated based on measurement data in high temperature test operation. And it is confirmed the adequacy of heat exchanger designing method by comparison of evaluated value with designed value.

Journal Articles

Performance test of HTTR

Nakagawa, Shigeaki; Tachibana, Yukio; Takamatsu, Kuniyoshi; Ueta, Shohei; Hanawa, Satoshi

Nuclear Engineering and Design, 233(1-3), p.291 - 300, 2004/10

 Times Cited Count:8 Percentile:48.76(Nuclear Science & Technology)

The High Temperature Gas-cooled Reactor (HTGR) is particularly attractive due to its capability of producing high temperature helium gas and due to its inherent safety characteristics. The High Temperature Engineering Test Reactor (HTTR), which is the first HTGR in Japan, was successfully constructed at the Oarai Research Establishment of the Japan Atomic Energy Research Institute. The HTTR achieved full power of 30MW at a reactor outlet coolant temperature of about 850$$^{circ}$$C on December 7, 2001 during the "rise-to-power tests". Two kinds of tests were carried out during the "rise-to-power tests". One is commissioning test to get operation permit by the government and another is test to confirm a performance of the reactor, heat exchanger, control system. From the test results of the "rise-to-power tests" up to 30MW, the functionality of the reactor and the cooling system were confirmed, and it was also confirmed that an operation of reactor facility can be performed safely.

Journal Articles

Performance test of the HTTR

Tanaka, Toshiyuki; Okubo, Minoru; Iyoku, Tatsuo; Kunitomi, Kazuhiko; Takeda, Takeshi; Sakaba, Nariaki; Saito, Kenji

Nihon Genshiryoku Gakkai-Shi, 41(6), p.686 - 698, 1999/00

 Times Cited Count:4 Percentile:34.76(Nuclear Science & Technology)

no abstracts in English

4 (Records 1-4 displayed on this page)
  • 1